SR EN 61000-4-5:2007
Compatibilitate electromagnetică (CEM). Partea 4-5: Tehnici de încercare şi măsurare. Încercări de imunitate la unde de şoc
Relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and electronic equipment. The object of this standard is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to surges. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This standard defines: - a range of test levels; - test equipment; - test setups; - test procedures. The task of the described laboratory test is to find the reaction of the EUT under specified operational conditions, to surge voltages caused by switching and lightning effects at certain threat levels. It is not intended to test the capability of the EUT's insulation to withstand high-
Status :
Anulat
Data aprobării : 01.06.2007
Data publicării : 03.06.2007
Data anulării : 19.06.2017
Număr de pagini : 101
ICS : 33.100.20 Imunitate
Comitet tehnic : 30 - Compatibilitate electromagnetică şi perturbaţii radioelectrice
- Inlocuieste SR EN 61000-4-5:1999
- Inlocuieste SR EN 61000-4-5:1999/A1:2003
- Inlocuit prin SR EN 61000-4-5:2015