SR EN ISO 10497:2023
Încercări ale aparatelor de robinetărie. Cerințe ale încercării la foc
This document specifies fire type-testing requirements and a fire type-test method for soft- and metal-seated isolation valves with one or more obturators. It is not applicable to the testing requirements for valve actuators other than manually operated gearboxes or similar mechanisms when these form part of the normal valve assembly. Other types of valve actuators (e.g. electrical, pneumatic or hydraulic) can need special protection to operate in the environment considered in this valve test, and the fire testing of such actuators is outside the scope of this document. This document specifies the measurement and assessment criteria for: a) through-seat leakage; b) external leakage; c) cavity overpressure relief of double-seated valves; d) operability. This document specifies the rules whereby the fire-type testing qualification for a valve can be extended to untested sizes, pressure ratings and materials of construction of the same basic design type. Fire test reports of valves tested according to previous editions of this document are acceptable when submitted together with the ful
Status :
In vigoare
Data aprobării : 31.01.2023
Număr de pagini : 30
ICS : 23.060.01 Robinetarie în general
Comitet tehnic : 89 - Robinetărie industrială
- Inlocuieste SR EN ISO 10497:2010
EN