SR EN 50342-1:2016/A2:2021
Baterii de acumulatoare cu plumb pentru pornire. Partea 1: Prescripţii generale şi metode de încercare
TC21X working group 3 has been agree to implement following changes to EN 50342-1:2015/1:2018 - Deletion of high current discharge after water consumption test. This is not needed as a dedicated corrosion test is available in the document. - Limitation of the maximum discharge time in cranking performance test. Batteries with high power capability might be damaged if discharge until the cut off voltage of 6,0 V is reached. To prevent this the maximum discharge time of the second step of the cranking performance test has been limited to 180 s.
Status :
In vigoare
Data aprobării : 29.11.2021
Număr de pagini : 5
ICS : 29.220.20 Acumulatoare si baterii acide
Comitet tehnic : 161 - Acumulatoare şi tehnologii pentru celule cu combustibil
- Modifica SR EN 50342-1:2016
EN