SR EN 50306-2:2020
Aplicații feroviare. Cabluri pentru material rulant feroviar având performanțe particulare de comportare la foc. Cabluri cu izolație redusă. Partea 2: Cabluri cu un conductor
This document specifies requirements for, and constructions and dimensions of, single core cables, rated voltage U0 / U = 300 /300 V, of the following type: Unscreened (0,5 mm2 to 2,5 mm2 single core) These cables are rated for occasional thermal stresses causing ageing equivalent to continuous operational life at a temperature of 105 °C. For standard cables, this is determined by the acceptance test defined in EN 50305, using accelerated long-term (5 000 h) thermal ageing indicating a 125 °C/20 000 h temperature index. If the customer were to require lifetime predictions, this would be demonstrated based on the temperature index of the product as supplied by the manufacturer. The maximum temperature for short circuit conditions is 160 °C based on duration of 5 s. Under fire conditions the cables exhibit special performance characteristics in respect of maximum permissible flame propagation (flame spread) and maximum permissible emission of smoke and toxic gases. These requirements are specified to permit the cables to satisfy Hazard Level 3 of EN 45545 1 and EN 45545 2. EN 50
Status :
In vigoare
Data aprobării : 31.07.2020
Număr de pagini : 18
ICS : 13.220.40 Comportamentul la foc si inflamabilitatea materialelor si produselor,29.060.20 Cabluri,45.060.01 Material rulant pentru cai ferate în general
Comitet tehnic : 159 - Cabluri electrice
- Inlocuieste SR EN 50306-2:2003