SR EN 81-72:2015

Safety rules for the construction and installation of lifts - Particular applications for passenger and goods passenger lifts - Part 72: Firefighters lifts

1.1 This European Standard specifies the additional or deviating requirements to EN 81-20 for new passenger and goods passenger lifts, which may be used for firefighting and evacuation purposes under firefighters control. 1.2 This European Standard applies, when the following conditions are fulfilled: - the lift well and the lift environment are designed to restrict the ingress of fire, heat and smoke to the lift well, machinery spaces and safe areas; - the building design limits the flow of water into the lift well; - the firefighters lift is not an escape route, such as staircases; - the lift well and the lift environment are fire protected for at least to the same level as the building structure; - the power supply is secure and reliable; - the electrical cable providing power to the lift is fire protected to the same fire protection level as given to the lift well structure; - a suitable maintenance and verification plan is implemented. 1.3 This European Standard does not cover: - the use of lifts with partially enclosed wells for use as firefighters lifts; - lifts install

34.12

Status : Withdrawn
Approval date : 9/30/2015
Withdrawal date : 8/31/2020
Number of pages : 48
ICS : 91.140.90 Lifts. Escalators
Technical Committee : 85 - Cranes

Relations with other standards: